SOLAR KERBEROS 320.H
basic parameters
- Recommended boiler volume: 160 - 300 litres
- Typical installed: approx. 2,5 kWp
- Recommended heater input: 2 - 2.5 kW
- Grid heating backup: YES
- Control: touchscreen (video)
- Production / consumption monitoring: YES
- Monitoring history: 10 days
- Utilization of energy surpluses: YES - Output to the secondary heater
- Recommended power input of the secondary heater: 2 - 2.5 kW
- Separate thermostat with secondary heater sensor: YES
- Separate thermal fuse with secondary heater sensor: YES
- Grid backup of the secondary heater: NE
- The output to the secondary heater is active after reaching the "solar" temperature in the primary boiler
- GSM based remote monitoring: optional
TECHNICal DATA
- Input open-circuit voltage (limits): 200 - 340 V
- MPP tracker range: 140 - 310 V
- Maximum current: 10 A
- Maximum efficiency: 99%
- Thermal fuse: YES electronic
- Mains connection: 230 V / 50 Hz, 16 A fuse
- Ingress protection IP20
Documents to download here
Installation video here
warning
Panels are available in various designs on the market, and if the technical requirements are met, it is not necessary to follow the recommended panel performance. The maximum idle input voltage must be observed in all circumstances - the negative thermal coefficient of the PV panels must be taken into account!